          | ,Standard contact blocks dimensions  | 
         
        
            | 
            | 
            | 
         
        
            | 
          ,Standard types of contact block and 
            assembly method  | 
         
        
           Short contact block is available in 1a, 1b, 1a1b, 2a and 2b. The contact may be increased to 2a2b by repl- 
          acing the short block with the long one. If more conta- 
            cts are needed, just add the short one to the long one (The short 
            one is not designed for being added by other 
            block at its rear end). 3a, 3b, 3a3b, 4a and 4b will be available 
            with one-long-one-short blocks. By replacing the short block with 
            another long one and becoming two-long blocks, 4a4b will be obtainable. 
           | 
         
       
      
        
          | ,Contact rating  | 
         
        
          
               
                | AC | 
                 Inductive  load  | 
                AC125V  | 
                AC250  | 
                AC440V  | 
                AC600V  | 
                DC | 
                Inductive  load  | 
                DC125V | 
                DC250V | 
                dc380V | 
               
               
                6A  | 
                4A  | 
                2A  | 
                1A  | 
                0.5A  | 
                0.2A  | 
                0.1A  | 
               
               
                | Resistive  load  | 
                10A  | 
                6A  | 
                4A  | 
                1.5A  | 
                Resistive  load  | 
                2A  | 
                0.6A  | 
                0.2A  | 
               
              | 
         
        
          | ,Characteristics | 
         
        
          
            
              |  Ambient temperature  | 
                -20<C ~ +60<C  | 
               
            
              |  Humidity  | 
               45 ~ 85%RH  | 
               
            
              |  Contact resistance  | 
                  50mΩmax.(initial 
                  value)  | 
               
            
              |  Insulation resistance  | 
                  100mΩmin.(at 
                  500VDC) | 
               
            
              |  Dielectric strength  | 
               2500VAC, 50/60HZ for 1 minute  | 
               
            
              |   Service life  | 
                Mechanically  | 
              Push Button/ Illuminated Push Button (Momentary) 3,000,000,Others 500,000  | 
             
            
              |  Electrically  | 
               500,000 operations  | 
             
            | 
         
       
      
      
        
           Type  | 
          TC-1A  | 
          TC-1B  | 
          TC-1C  | 
          TC-2A  | 
          TC-2B  | 
          TC-2C  | 
         
        
           Contact  | 
          1a  | 
          1b  | 
          1a1b  | 
          2a  | 
          2b  | 
          2a2b  | 
         
        
           Contact 
            Arrangemen  | 
            | 
            | 
            | 
            | 
            | 
            | 
         
       
      
        
           Type  | 
          TC-3A  | 
          TC-3B  | 
          TC-3C  | 
          TC-4A  | 
          TC-4B  | 
          TC-4C  | 
         
        
           Contact  | 
          3a  | 
          3b  | 
          3a3b  | 
          4a  | 
          4b  | 
          4a4b  | 
         
        
           Contact 
    Arrangemen  | 
            | 
            | 
            | 
            | 
            | 
            | 
         
       
       
     |