¡¡back
90 ¡ã operation on one side isposs-
ibleby simply changing the direction
of the cam.
 
 
 
 
¡¡Relationship of cam to opertion as observed from the rear of switch
¡¡.Characteristics
Operating speed 1mm to 2m/sec (with Type WLCA2)
Operating frequency Mechanically: 120 operations/min.
Electrically: 30 operations/min.
Contact resistance 15mW max. (initial).
Insulation resistance 100MW min. (at 500VDC)
Dielectric strength 1,000VAC, 50/60Hz for 1 minute between non-continuous terminals;
2,200VAC, 50/60Hz for 1 minute between each terminal and non-current-carrying metal part and between each terminal and ground
Temperature¡¡rise 50 degrees max.
Vibration Malfunction durability: 10 to 55Hz;
1.5mm double amplitude
Shock Mechanical durability :
Approx. 1,000m/sec2 (approx. 100G¡¯s)
Malfunction durability :
Approx. 300m/sec2(approx. 30G¡¯s)
Ambient temperature Operating: -50 to + 80¡ãc
Humidity 95%RH max.
Service life Mechanically:
15,000,000 operations min.
Electrically:
500,000 operations min.
Weight Approx. 275g (with Type TZ-5104)
Degree of protection IEC 529 class IP67
 